Перейти к основному содержанию

The Kenmore Elite HE3 is 7.2 cu. ft. capacity electric dryer by Kenmore.

318вопросов Показать все

Changed 4-prong to 3-prong after a move.

Kenmore Elite He3 powers on, but will not work. Tested the electricity from outlet and wires (by a retired electrician). He says all work. He advised calling an appliance person to test motherboard, circuits. Each person I telephoned has never heard of a motherboard, circuit board. Please help.

Kismet

Отвечено! Посмотреть ответ У меня та же проблема

Это хороший вопрос?

Оценка 0
2 Комментариев

They would just call it a different name, like control board or something similar. This pdf should help with the diagnosis. Kenmore-Elite-HE3-Dryer-Tech-Sheet.pdf

из

@kismet post some images of your outlet, the plug and how it is wired into the machine. Use this guide Adding images to an existing question for that It will allow us to see what you see.

из

Добавить комментарий

1 ответ

Выбранное решение

The 4 prong power cord had the ground (green) wire screwed to the cabinet and the 3 other wires were screwed to the terminal block. A 3 prong power cord doesn’t have a ground (green) wire. The middle terminal on the block has a white (neutral) wire that needs to be screwed to the cabinet where the ground (green) wire was attached. This is a common mistake.

Был ли этот ответ полезен?

Оценка 3
Добавить комментарий

Добавьте свой ответ

Kismet будет вечно благодарен.