Why does my yahama amp keep blowing fuse?

Hello. Guys, I have a yamaha dsp a590, fuse keeps.blowing. Fuse is 3.15a. Located by the voltage switcher. Please assist.

Ответ на этот вопрос У меня та же проблема

Это хороший вопрос?

Оценка 0
Добавить комментарий

Manta Driver Kit

112 bits for every fix.

Upgrade Your Toolbox

Manta Driver Kit

Upgrade Your Toolbox

2 Ответов

Наиболее полезный ответ

@julzmatt

Double check the voltage selector and see what it is set at. If it is okay then your amp may have a short circuit somewhere in the power line of the main board. You will have to disassemble it and see if you can visually identify components that look damaged or missing. Post some good images of your board as well as the location of the fuse etc. with your question. Adding images to an existing question

You can download the service manual for this amp on here

Был ли этот ответ полезен?

Оценка 1
Добавить комментарий

your output stage is shorted.

Был ли этот ответ полезен?

Оценка 0
Добавить комментарий