  1. AT-LP60X Mechanical Reset, Remove Power From The Turntable: шаг 1, изображение 1 из 1
    • Unplug the power source located on the back of the turntable.

  2. AT-LP60X Mechanical Reset, Press The Stop Button: шаг 2, изображение 1 из 1
    • Press the stop button located at the front of the turntable one time.

    • During this step, remove your record (if one is on the turntable) and remove the black felt mat.

  3. AT-LP60X Mechanical Reset, Perform Mechanical Reset: шаг 3, изображение 1 из 1
    • With your right hand, hold the tone arm in the rest so that it does not move.

    • With your left hand, slowly rotate the platter clockwise until you hear a series of clicks.

    • After hearing the series of clicks, the cam gear assembly should not rotate while the platter is spinning - if the cam gear is still rotating, press the stop button again and repeat Step 3.

    • Cam gear assembly - white gear visible through holes of the platter.

    • Allowing the tone arm to move freely during this process can result in the stylus being broken.