A failed impulse coupling can cause the crankshaft gear to break off. This will cause the aircraft's magneto not to work therefore the aircraft's engine will not start.

Запчасти

Никакие детали не требуются.

Use a 9/16 wrench to unscrew the nut on the drive shaft. Use a 9/16 wrench to unscrew the nut on the drive shaft.
  • Use a 9/16 wrench to unscrew the nut on the drive shaft.

Добавить комментарий

Remove the lock washer underneath the nut.
  • Remove the lock washer underneath the nut.

Добавить комментарий

Pull away the impulse coupling. Pull away the impulse coupling.
  • Pull away the impulse coupling.

Добавить комментарий

Заключение

To reassemble your device, follow these instructions in reverse order.