Введение

If you need to replace a Brad Nailer Pressure Regulator Chamber Gasket, follow the steps outlined in this guide. For this guide, you will need a 4mm Allen wrench. The steps outlined are relatively easy to follow.

Запчасти

Никакие детали не требуются.

  1. Using a 4mm Allen wrench, remove the 4 Allen screws, 44mm in length, from the yellow cap on the back of the brad nailer.
    • Using a 4mm Allen wrench, remove the 4 Allen screws, 44mm in length, from the yellow cap on the back of the brad nailer.

  2. Remove the yellow cap to reveal the gasket.
    • Remove the yellow cap to reveal the gasket.

    • Keep the nailer upright so the piston does not fall out. If the piston falls out, simply put it back in place.

    • Remove the faulty gasket and replace it with a new gasket.

Заключение

To reassemble your device, follow these instructions in reverse order.