+[title] Identifying dead cells
+[* black] Battery pack works by putting individual cells in parallel / series. Each cell has a nominal voltage / capacity and they are put together to give the whole battery pack it's global voltage / capacity.
+[* black] Here we have a 3s2p battery pack. This means that you have 3 serial attached blocks of 2 parallel cells.
+[* black] The lefmost block seems dead, the cells reads a steady 0 volts on my multimeter.
+[* black] The 2 other block show ~3.6 V which means they are still alive, great !
+[* red] I haven't tested individual cells from the 2 working blocks for a good reason. This battery pack has been stored for several monthes, if only one cell in the block was dead, the other (good) one would have discharged in it until it also dies ( which is what must have happen in dead block )