Перейти к основному содержанию

There are many versions of these Saeco coffee machines. They are very similar in structure and many repairs are similar.

9вопросов Показать все

After switch on: priming star for few seconds then E05 error

Dear,

Circuit priming message loops at beginning, then straigth away E05 error and asking to restart the machine, I did few times without sucess.

I opened the machine, and I can`t see any leak.

Any recommendation please?

My  coffee machine is Royal gran crema

Отвечено! Посмотреть ответ У меня та же проблема

Это хороший вопрос?

Оценка 0
1 Комментарий

Hi . The problem with E05 is generated of many SAECO coffee machine , I had this problem and I fixed it . See the video below and I am sure it will helps you .

https://youtu.be/0YR-xtacx1U

из

Добавить комментарий

1 ответ

Выбранное решение

Error code 05 means that the flow meter does not give a signal. Now you have to search: is the flowmeter blocked or broken? Or the water cannot pass through, e.g. because the heater or the pump is calcified. In Saeco Royal Pumpe austauschen the flowmeter can be seen in step 6, picture 2. Open the flowmeter and clean it, it's easy.

Был ли этот ответ полезен?

Оценка 1
Добавить комментарий

Добавьте свой ответ

anass будет вечно благодарен.
Просмотр статистики:

За последние 24часов: 1

За последние 7 дней: 36

За последние 30 дней: 172

За всё время: 7,140